COA BY Janoshik Ltd. (Independent Analytical Laboratory)

CS-re10-1006

  • COA Task Number: 242011
  • Unique Key: GC4M4V1A6WUS
  • 13 OCT 2026
PURITY
99.531%,
99.619%,
99.498%.
PEPTIDE CONTENT
11.92 mg,
11.51 mg,
11.66 mg.
ENDOTOXI1N
2.606 EU/vial
HEAVY METALS
Pass(Not Detected)
IDENTITY
Confirmed
Retatrutid (GLP-3) 10mg
PRODUCTS

Retatrutid (GLP-3) 10mg

View product specifications, research information, and ordering details.
VIEW PRODUCT DETAILS
01

Sample Identification

PRODUCT GLP-3 (Retatrutide) 10mg BATCH CS-re10-1006
LABORATORY Janoshik Analytical TEST REPORT NOS. #242011 · #242012 · #242013
CLIENT Cocer Peptides MANUFACTURER cocerpeptides.com
VERIFICATION KEYS GC4M4V1A6WUS · VQ4HAMNNDX2Y · DHZ8KURDUIY1 DOCUMENT TYPE Third-Party Laboratory Test Reports
REPORTING PERIOD 29 Aug – 13 Oct 2026    

 

 

02

Purity & Quality Analysis

PURITY 99.531%, 99.619%, 99.498%

HPLC Purity / Test Report #242011

PEPTIDE CONTENT 11.92 mg, 11.51 mg, 11.66 mg / vial

GLP-3 (Retatrutide) Content / Test Report #242011

ENDOTOXIN 2.606 EU / vial

Endotoxin Test / Test Report #242012

HEAVY METALS
Arsenic (As) —
Not Detected
Cadmium (Cd) —
Not Detected
Lead (Pb) —
Not Detected
Mercury (Hg) —
Not Detected

Heavy Metals Analysis Test Report #242013

03

Testing Methods & COA

CERTIFICATE OF ANALYSIS

PRODUCT IDENTIFICATION

GLP-3 (Retatrutide) 10mg

ANALYSIS SUMMARY

This MOTS-c 10mg batch was independently tested by Janoshik Analytical across three separate test reports. Testing covered peptide content and purity, heavy metals including arsenic, cadmium, lead and mercury, and endotoxin.
The reported results were 11.92 mg, 11.51 mg, 11.66 mg/vial peptide content, 99.531%, 99.619%, 99.498% purity, no detected As, Cd, Pb or Hg, and 2.606 EU/vial endotoxin.

PURITY RESULT
99.531%,
99.619%,
99.498%
PEPTIDE CONTENT
11.92 mg,
11.51 mg,
11.66 mg
/ vial
THIRD-PARTY VERIFICATION

Independent third-party testing was completed by Janoshik Analytical for Cocer Peptides batch CS-re10-1006. The three reports cover peptide content and purity, heavy metals, and endotoxin testing.

TEST REPORT NOS.
#242011 · #242012 · #242013
REPORTING PERIOD
28 Aug – 05 Oct 2026
LAB
Janoshik Analytical
BATCH
CS-re10-1006
04

Test History for GLP-3 (Retatrutide)10mg

Independent third-party testing history for GLP-3 (Retatrutide)10mg.

GLP-3 (Retatrutide)10mg · Batch CS-re10-1006 · Janoshik Analytical

This laboratory testing information is provided for research reference only. Results apply only to the tested sample(s) associated with the reports shown on this page and may not represent other batches. Products are intended for laboratory research and analytical use only, not for human or veterinary use. Original laboratory reports and verification records should be regarded as the authoritative source.